| PRODUCTS |
|
| |
|
600 VA Line Interactive UPS |
IGA PC GUARD
|
|
 |
|
Features
Intelligent shut down software
Cute and compact design
EMI ,RFI ,Surge protection
15 minutes back up on single PC
Cold start on 15” / 17” CRT / TFT monitor
Off Line Battery charging
Zero battery power drain on low battery trip
Sinusoidal out put in mains mode , simulated / quasi sine wave in battery mode |
 |
|
|
500VA/750 VA/ 1kVA Extended Back Up Line Interactive |
IGA MINI NET GUARD -1
|
|
 |
|
Features
Wide input voltage 145 - 270V
Cute and compact design
EMI ,RFI ,Surge protection
30 minutes – 4 Hr back up depending on load
Off Line Battery charging
Sinusoidal out put in mains mode ,simulated /
.. quasi sine wave in battery mode
Over load and short circuit protection
|
 |
| |
|
2000 VA - 5000VA Line Interactive UPS |
IGA NET GUARD
|
|
 |
|
Features
Wide input voltage 150-280V
EMI ,RFI ,Surge protection
30 minutes to 4 Hrs back up depending on load
Off Line Battery charging
Ranges from 2 kVA to 5 kVA
Over load and short circuit protection
Sinusoidal out put in mains mode ,and simulated
...sine wave in battery mode
Load Level , Battery level Indication.
|
 |
| |
|
|
|
1000-6000VA Line Interactive Sine wave |
UPS: IGA SMART GUARD
|
|
 |
|
Features
Wide input voltage 150-280V
Intelligent shut down and monitoring software
EMI ,RFI ,Surge protection
30 minutes to 4 Hrs back up depending on load
Off Line Battery charging
Zero battery power drain on low battery trip
Ranges from 1kVA to 6 kVA
Over load and short circuit protection
Sine wave out put in both mains and battery mode
|
 |
| |
|
|
|
1-30kVA True On Line UPS |
IGA TRUE ONLINE
|
|
 |
|
Features
Wide input voltage 230V / 415 V (- 30% to +15 %) Double Conversion online EMI ,RFI ,Surge protection 30 minutes to 4 Hrs back up depending on load Mosfet/IGBT based PWM Technology Static Switch (option) and manual bypass switch 1 ph in : 1 ph out- 1kVA,2kVA,3kVA,4kVA,5 kVA,6kVA,7.5kVA ...ranges. 3 ph in : 3 ph out- 5kVA,6kVA,7.5kVA,10kVA,15 ...kVA,20kVA,30kVA ranges. Pure Sine wave out put with THD <2% for linear load ,<5 % ...non linear load Over load and short circuit protection
|
 |
| |
|
|
|
1-20kVA Intelligent On Line UPS |
IGA SATURN
|
|
 |
|
Features
Wide input voltage 150 - 280V/300 - 470 V
Active Power factor correction with input pf >0.98
Double Conversion online
EMI ,RFI ,Surge protection
30 minutes to 4 Hrs back up depending on load
IGBT based technology
Built in Static bypass ensures uninterrupted transfer & ...retransfer of load
Intelligent shut down and remote monitoring software
SNMP (option) for browsing through network and remote shut ...down
1 ph in : 1 ph out- 1kVA,2kVA,3kVA,4kVA,5 ...kVA,6kVA,7.5kVA,10kVA ranges.
3 ph in : 1 ph out- 10kVA,15 kVA,20kVA,30kVA ranges.
Pure Sine wave out put with THD <2% for linear load ,<5% for ...non linear load
Over load and short circuit protection
|
 |
| |
|
|
SATURN KD 1-3
|
1-20 kVA Intelligent online UPS |
|
 |
Widest Input voltage Range
Active Power factor correction with input pf >0.98
True online with Double Conversion ,IGBT , Sinusoidal PWM Switching
EMI ,RFI ,Surge protection
DSP Technology guarantees high performance & reliability
Smart RS-232 Communication port with bundled smart UPS Monitoring Soft ware
Built in Static bypass ensures uninterrupted transfer & ... retransfer of load
ntelligent shut down and remote monitoring software
SNMP (option) for browsing through network and remote shut down
Audible alarm mute
Cold start function
Auto self – testing System while turning on the UPS
Maintenance by pass switch , Built in static bypass
Over load and short circuit protection |
|
| |
|
|
Saturn KD 6 -20
|
IGA SATURN KD SERIES |
|
 |
Widest Input voltage Range
Active Power factor correction with input pf >0.98
True online with Double Conversion ,IGBT , Sinusoidal PWM Switching
EMI ,RFI ,Surge protection
DSP Technology guarantees high performance & reliability
Smart RS-232 Communication port with bundled smart UPS Monitoring Soft ware
Built in Static bypass ensures uninterrupted transfer & ... retransfer of load
ntelligent shut down and remote monitoring software
SNMP (option) for browsing through network and remote shut down
Audible alarm mute
Cold start function
Auto self – testing System while turning on the UPS
Maintenance by pass switch , Built in static bypass
Over load and short circuit protection |
|
| |
|
|
|
500 VA - 5kVA Inverters |
IGA INVA SERIES
|
|
 |
|
Features
Square wave /Sine wave out put
Mosfet/IGBT based technology
EMI ,RFI ,Surge protection
1 hr to 6 Hrs back up depending on load
Smart Battery charging
Over load and short circuit protection.
500VA,750VA, 1kVA, 2kVA, 3kVA and 5 kVA ranges.
|
 |
| |
|
|
|
|
IGA HOME UPS
|
|
 |
|
Features
Multiple micro processor design
Compatible with both linear & Non linear load
Best suited for Home appliances ,Lights,Fans,TV’s
140 -270 V Input Range
THD less than 3%
Stronger charger to support batteries of 500AH up/ high ...efficiency design
750 VA/1.5 to 5 kVA range
|
 |
| |
|
|
|
IGA DC Power Supply |
IGA DC Power Supply
|
|
 |
|
Features
Charges 24V VRLA or Ni-Cd Batteries
Output power of 12.5 A/25 A/35 A
Compact size for wall mounting
220V +/-25 % input voltage range
Low emissions
Ambient temperature 0-50 Degree centigrade
LED indications for status of operation
Pilot lamps for input and out put
Isolated remote alarm contacts
Meters for input and output voltages
|
 |
| |
|
|
|
1kVA-300kVA Servo Controlled Voltage Stabilizers |
IGA SCVS
|
|
 |
|
Features
Wide input voltage window 120-290V
Compatible with DG Sets
Built in time delay for re-start
Built in under /over voltage protection
Short circuit protection through fuse/MCB
Correction rate >40V/Secs
Output regulation better than 1%
Single phase and three phase design
Air cooled as well as oil cooled designs
1-10kVA in 1 phase and 3-300kVA in 3Phase designs
No wave form distortion
Automatic/manual bypass facility
|
 |
| |
|
|
|
15 - 400 A Battery Charger |
IGA BATTERY CHARGER
|
|
 |
|
Features
Input and output circuit with breaker protection.
Float-equalizing charge selected by switch with individual turn ...counting dialed option timer adjustment.
On board settings current limiting.
80mm x 80mm class 2.5 indicating voltmeter and ammeter
Front panel status indicating LED.
Visible and audible alarm.
Fuse failure and over current announciation.
|
 |
| |
|
|
|
|
IGA APFC
|
|
 |
|
Features
Automatic multi – step power factor control (upto 12steps)
Microprocessor based controller with four-quadrant ...measurement .
Self-adaptable with short reaction time for extremely ...fluctuating power levels.
Provided with reliable, long lasting components including heavy ...duty, dry type KVAR rated Capacitors.
Application based system, configuration with Multi-bank ...capacitors, multi stage protection and safety devices.
Surge suppression and harmonic trapping inductors are ...incorporated as a optional features.
Door mounted, intuitive,programmable user interface.
Wide ranges available from 20 KVAr to 1000 KVAr in single ...module. Multi module construction for higher ratings. |
 |
| |
10kVA – 80kVA UPS
IG 3100 Series
|
IGA ON LINE UPS IG 3100 |
|
 |
|
Features
100 % digital Technology
True online double conversion design
Three phases in Single Phases Out
Sinusoidal PWM
Extended run time
Generator compatible
Display of load / battery capacity
LED/LCD display for overload, online, battery status.
Cold start on battery
Intelligent Battery management
Optional SNMP Card
RS 232 |
 |
| |
IGA Data Center UPS 3300 Series
|
|
ELITE/ELITE MAX - 60kVA to 300 kVA Online UPS
|
|
 |
|
Features
Reduces power consumption for Data centers
Fluid cooling system to reduce heat dissipation THDi <5% with low harmonic content
THF Inverter Technology ( Transformerless)in all models
High Efficiency : Eco- mode (97%)/ Normal Mode (92%)
|
 |
| |
IGA Industrial UPS |
|
CUBE STR 7.5 kVA to 100kVA |
|
 |
|
Transformer less On-line double conversion power topology
Lower Weight & Dimensions'
High frequency inverter & rectifier by means of IGBT
Transistors. Power factor > 0.99
Total Input current harmonic distortion (THDi) of 3%
High Efficiency > 92%
Parallel redundant configurations
Maintenance bypass as standard
Wide input voltage range
Intelligent systems to charge the batteries( Batt-Watch)
Communication ports RS-232 , RS 422 and AS -400as standard
Automatic Battery Test , Soft start up
Monitoring and Management software |
 |
| |
|
|
|
| |
|
|
|
| |
| |
|
|
| |
|
|
|
 |
 |
| |